Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

Tesamorelin lab test from Forge Performance Co., August 2026

Kovera Labs tested Tesamorelin from Forge Performance Co. on Aug 8, 2026. It measured 99.663% purity and 10.59 mg against 10 mg on the label.

HPLC purity
99.663%
✓ Excellent
Excellent means 98% or higher.
In the vial
10.59 mgThe label says 10 mg, so 6% more.
Tested by
Kovera Labs
Tested on
Sterility
✓ Pass · no growth
Lot
TESA10-2608-01-WHT
See the certificate ↓

Confirmed on Kovera Labs' portal · checked Aug 8, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeT3XVBCO

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.663%How much of what's in the vial is the target compound
Amount in the vial10.59 mglabel says 10 mg · 6% moreWhether you get the amount on the label
EndotoxinPassIs it safe to inject? Checks for bacterial toxins
SterilityPass — no growthLab's note: No GrowthIs it safe to inject? Checks for live bacteria or fungi
Heavy metalsNot recordedCould there be metal contamination?

Not recorded for this test: heavy metals. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 10 mg · Lab measured 10.59 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 6% more means in a syringe

106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.6 mg using the measured mass, against 2.5 mg on the label — 6% more.

Certificate of analysis

Original document
Issued by Kovera Labs · Aug 8, 2026 · Batch TESA10-2608-01-WHT

About this test

How this certificate was checked

Report numberKVR-2026-46D3F5
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validKovera Labs' portal doesn't show the numbers, so they can't be compared there.
Submitted viaShop panel (bulk upload)
Counts asOne lab testCounts toward Forge Performance Co.'s Trust Score until Aug 8, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@user-3642 👑 Legend
Summary

Independent HPLC purity analysis of Tesamorelin from Forge Performance Co., performed by Kovera Labs on August 8, 2026. Reported purity: 99.663%. Net content: 10.59 mg against 10 mg labeled (106% of label). Endotoxins: PASS. Sterility: passed. Batch TESA10-2608-01-WHT. Sample source: shop-provided. Certificate of analysis attached.

Other lots of Tesamorelin from Forge Performance Co.

LotTestedLabPurityvs labelLab's portal
TESA10-2610-01-BLK-SLVOct 15, 2026Freedom Diagnostics99.05%113% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

7 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.