ForumRetatrutide: 1, 2 or 3 mL of BAC water — what do you use, and why? · Retatrutide · 10 replies

Tesamorelin 10mg lab test from UKMAXX, November 2026

Janoshik Labs tested Tesamorelin 10mg from UKMAXX on Nov 6, 2026. It measured 98.112% purity and 9.63 mg against 10 mg on the label.

HPLC purity
98.112%
✓ Excellent
Excellent means 98% or higher.
In the vial
9.63 mgThe label says 10 mg, so 4% less.
Tested by
Janoshik Labs
Tested on
Lot
TSM10-2026-10-A
See the certificate ↓

Confirmed on Janoshik Labs' portal · checked Nov 6, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeE5KTRP5QCQPA

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)98.112%How much of what's in the vial is the target compound
Amount in the vial9.63 mglabel says 10 mg · 4% lessWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 9.63 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 4% less means in a syringe

96% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.4 mg using the measured mass, against 2.5 mg on the label — 4% less.

Certificate of analysis

Original document
Issued by Janoshik Labs · Nov 6, 2026 · Batch TSM10-2026-10-A

About this test

How this certificate was checked

Report number248926
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there.
Submitted viaShop panel (bulk upload)
Counts asOne lab testCounts toward UKMAXX's Trust Score until Nov 6, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@UKMAXX 💬 Contributor
Summary

Independent HPLC purity analysis of Tesamorelin from UKMAXX, performed by Janoshik Labs on November 6, 2026. Reported purity: 98.112%. Net content: 9.63 mg against 10 mg labeled (96% of label). Batch TSM10-2026-10-A. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

5 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.