ForumRetatrutide: 1, 2 or 3 mL of BAC water — what do you use, and why? · Retatrutide · 10 replies

GHK-Cu 100mg lab test from Forge Performance Co., November 2026

Freedom Diagnostics tested GHK-Cu 100mg from Forge Performance Co. on Nov 13, 2026. It measured 99.38% purity and 117.51 mg against 100 mg on the label.

HPLC purity
99.38%
✓ Excellent
Excellent means 98% or higher.
In the vial
117.51 mgThe label says 100 mg, so 18% more.
Tested on
Lot
GHKCU100-2611-01-CLR-CLR
See the certificate ↓

Confirmed on Freedom Diagnostics' portal · checked Nov 13, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeForg2611123039

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.38%How much of what's in the vial is the target compound
Amount in the vial117.51 mglabel says 100 mg · 18% moreWhether you get the amount on the label
EndotoxinPassIs it safe to inject? Checks for bacterial toxins
Heavy metalsPass — Arsenic, Cadmium, Lead and Mercury below limitsCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 100 mg · Lab measured 117.51 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 18% more means in a syringe

118% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 29.4 mg using the measured mass, against 25 mg on the label — 18% more.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Nov 13, 2026 · Batch GHKCU100-2611-01-CLR-CLR

About this test

How this certificate was checked

Report number2611123039
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Submitted viaShop panel (bulk upload)
Counts asOne lab testCounts toward Forge Performance Co.'s Trust Score until Nov 13, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@user-3642 💬 Contributor
Summary

Independent HPLC purity analysis of GHK-Cu from Forge Performance Co., performed by Freedom Diagnostics on November 13, 2026. Reported purity: 99.38%. Net content: 117.51 mg against 100 mg labeled (118% of label). Tested content exceeds the labeled amount by 18%. Endotoxins: Pass. Heavy metals: Pass — Arsenic, Cadmium, Lead and Mercury below limits. Batch GHKCU100-2611-01-CLR-CLR. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

7 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.