BPC-157 5mg lab test from UKMAXX, August 2026
Janoshik Labs tested BPC-157 5mg from UKMAXX on Aug 27, 2026. It measured 99.746% purity and 4.84 mg against 5 mg on the label.
- In the vial
- 4.84 mgThe label says 5 mg, so 3% less.
- Tested by
- Janoshik Labs
- Tested on
- Lot
- BPC-2026-05-A
Confirmed on Janoshik Labs' portal · checked Aug 27, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
AK9GVE8V85T7Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 949 BPC-157 lab tests →BPC-157 pricesUKMAXX reviews and all 10 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.746% | How much of what's in the vial is the target compound |
| Amount in the vial | 4.84 mglabel says 5 mg · 3% less | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 5 mg · Lab measured 4.84 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 3% less means in a syringe
97% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.2 mg using the measured mass, against 1.3 mg on the label — 3% less.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 208699 |
|---|---|
| On the lab's portal | ✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal. |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward UKMAXX's Trust Score until Aug 27, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | @UKMAXX 💬 Contributor |
Independent HPLC purity analysis of BPC-157 from UKMAXX, performed by Janoshik Labs on August 27, 2026. Reported purity: 99.746%. Net content: 4.84 mg against 5 mg labeled (97% of label). Batch BPC-2026-05-A. Sample source: shop-provided. Certificate of analysis attached.