COA -2026-YSMFIF matches ILS Laboratories's public record. So this test doesn't rest on our review alone — the lab confirms it too.
O4LWWOSBNot on file for this certificate: sterility and heavy metals. A purity figure says nothing about those.
Label 20 mg · Lab measured 20.93 mg
105% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 5.2 mg using the measured mass, against 5 mg on the label — 5% more.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | -2026-YSMFIF |
|---|---|
| Portal lookup | ✓ Lab-verified |
| PDF vs portal | ILS Laboratories's portal shows validity only |
| Submitted via | Peptigrity staff |
| Weight | Counts as one lab test |
Independent HPLC purity analysis of Tesamorelin from Crush Research, performed by ILS Laboratories on May 11, 2026. Reported purity: 99.37%. Net content: 20.93 mg against 20 mg labeled (105% of label). Endotoxins: 0.09 EU/mL. Batch CR-TSM20-0307-1. Sample source: shop-provided. Certificate of analysis attached.
| Lot | Tested | Lab | Purity | vs label | Status |
|---|---|---|---|---|---|
| CR-TESA20-0906 | 6 Sept 2026 | ILS Laboratories | 99.72% | 105% | Unverified |
| CR-TESA10MG-0828 | 24 Aug 2026 | ILS Laboratories | 99.55% | 105% | Unverified |
| CR-Tesa10-2607-Black | 10 Aug 2026 | ILS Laboratories | 99.73% | 106% | Unverified |
| CR-TESA20-2606-GRAY | 2 Jul 2026 | ILS Laboratories | 99.75% | 104% | Unverified |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.
Community discussion