Semax 30mg lab test from Peptide Partners, September 2026
Chromate tested Semax 30mg from Peptide Partners on Sep 2, 2026. It measured 99.418% purity and 27.66 mg against 30 mg on the label.
- In the vial
- 27.66 mgThe label says 30 mg, so 8% less.
- Tested by
- Chromate
- Tested on
- Lot
- SX2622
Confirmed on Chromate's portal · checked Sep 2, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
GLZ3KE38HYS6Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 335 Semax lab tests →Semax pricesPeptide Partners reviews and all 140 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.418% | How much of what's in the vial is the target compound |
| Amount in the vial | 27.66 mglabel says 30 mg · 8% less | Whether you get the amount on the label |
| Endotoxin | < 2.5 EU/vial | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | < 50 ppb | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.
What’s in the vial
Label 30 mg · Lab measured 27.66 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 8% less means in a syringe
92% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 6.9 mg using the measured mass, against 7.5 mg on the label — 8% less.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 39035 |
|---|---|
| On the lab's portal | ✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal. |
| What the portal shows | That the report is validChromate's portal doesn't show the numbers, so they can't be compared there. |
| Submitted via | Peptigrity staff |
| Counts as | One lab testCounts toward Peptide Partners' Trust Score until Sep 2, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | @Peptigrity 👑 Legend |
Independent HPLC purity analysis of SEMAX from Peptide Partners, performed by Chromate on September 2, 2026. Reported purity: 99.418%. Net content: 27.66 mg against 30 mg labeled (92% of label). Endotoxins: < 2.5 EU/vial. Heavy metals: < 50 ppb. Batch SX2622. Sample source: shop-provided. Certificate of analysis attached.
Other lots of Semax from Peptide Partners
| Lot | Tested | Lab | Purity | vs label | Lab's portal |
|---|---|---|---|---|---|
| SX202603 | Mar 31, 2026 | Kovera Labs | 99.921% | 99% of label | Not checked |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Related lab tests
The 332 other Semax tests on Peptigrity have a typical purity of 99.52%. This one is 99.418%.

Community discussion