ForumRetatrutide: 1, 2 or 3 mL of BAC water — what do you use, and why? · Retatrutide · 10 replies

Retatrutide 30mg lab test, lot 743, November 4, 2026

Freedom Diagnostics tested Retatrutide 30mg on Nov 4, 2026. The shop is withheld. It measured 99.98% purity and 31.7 mg against 30 mg on the label.

HPLC purity
99.98%
✓ Excellent
Excellent means 98% or higher.
In the vial
31.7 mgThe label says 30 mg, so 6% more.
Shop
Shop withheld
Tested on
Lot
743
See the certificate ↓

Confirmed on Freedom Diagnostics' portal · checked Nov 4, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeRivn2611041456

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.98%How much of what's in the vial is the target compound
Amount in the vial31.7 mglabel says 30 mg · 6% moreWhether you get the amount on the label
EndotoxinPassIs it safe to inject? Checks for bacterial toxins
Heavy metalsPass — Arsenic, Cadmium, Lead and Mercury below limitsCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.

What’s in the vial

Label 30 mg · Lab measured 31.7 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 6% more means in a syringe

106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 7.9 mg using the measured mass, against 7.5 mg on the label — 6% more.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Nov 4, 2026 · Batch 743

About this test

How this certificate was checked

Report number2611041456
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Submitted viaShop panel (bulk upload)
Counts asOne lab test
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byThe shop
Summary

Independent HPLC purity analysis of Retatrutide, performed by Freedom Diagnostics on November 4, 2026. Reported purity: 99.98%. Net content: 31.7 mg against 30 mg labeled (106% of label). Endotoxins: Pass. Heavy metals: Pass — Arsenic, Cadmium, Lead and Mercury below limits. Batch 743. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

4 tests

The 1,543 other Retatrutide tests on Peptigrity have a typical purity of 99.80%. This one is 99.98%.

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.