✓ Purity · passLab has no portalShop-provided sample

GHK-Cu × Evolve Biopep — lab test, April 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. The Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.How we weigh evidence →
HPLC Purity
98%
✓ Excellent purity only
PeptideGHK-Cu
See Evolve Biopep reviews & all 43 lab tests
↓ Download COA
COA on file — not portal-verified

This lab doesn't publish a public lookup, so we can't confirm the certificate against the lab's own record. The document was reviewed before publication, but it rests on our review alone.

What portal verification means →

Test results

8 data points
Purity
98%
Endotoxins
<1.25 EU/ml
Heavy metals
Not tested
Stated qty
60 mg
Tested qty
72.33 mg
Qty match
121% of labeled · +21%
Batch / Lot
EK-260406-KW
Container
Purple cap / Silver crimp / White label vial
Tested by
Ethos AnalyticsView profile →

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 60 mg · Lab measured 72.33 mg

121% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 18.1 mg using the measured mass, against 15 mg on the label — 21% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report numberEK-260406-KW
Portal lookupLab has no portalThis laboratory publishes no public lookup, so the report cannot be confirmed independently.
PDF vs portalEthos Analytics's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of KLOW from Evolve Biopep, performed by Ethos Analytics on April 9, 2026. Reported purity: 98%. Net content: 72.33 mg against 60 mg labeled (121% of label). Tested content exceeds the labeled amount by 21%. Endotoxins: <1.25 EU/ml. Batch EK-260406-KW. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by Ethos Analytics · Apr 09, 2026 · Batch EK-260406-KW

Other lots of GHK-Cu from Evolve Biopep

LotTestedLabPurityvs labelStatus
EK-260406-KW10 Apr 2026Ethos Analytics98%103%Lab has no portal
G5022627 Feb 2026Vanguard Laboratory99.8%114%Unverified
GW6012624 Feb 2026Vanguard Laboratory99.5%103%Unverified
EVOLVE3TM9EF23 Oct 2025Chromate98.533%101%Unverified

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

The 831 other GHK-Cu tests on Peptigrity range from 95.76% to 100.00%. This one sits at 98.00%.