COA 2608310652 matches freedomdiagnosticstesting.com's public record. So this test doesn't rest on our review alone — the lab confirms it too.
The portal confirms the certificate. It can't show that a vial you buy from Peptuvia is from this batch — compare the lot on yours.
G2608310652This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Label 10 mg · Lab measured 8.17 mg
82% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2 mg using the measured mass, against 2.5 mg on the label — 18% less.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | 2608310652 |
|---|---|
| Portal lookup | ✓ Lab-verified |
| PDF vs portal | freedomdiagnosticstesting.com's portal shows validity only |
| Weight | Listed for information — supplier-provided, not counted |
HPLC purity analysis of Ipamorelin 10mg sold by Peptuvia, ordered by its supplier and performed by freedomdiagnosticstesting.com on September 2, 2026. Reported purity: 99.61%. Net content: 8.17 mg against 10 mg labeled (82% of label). Tested content is 18% below the labeled amount. Endotoxins: Pass (2 replicates, LAL USP <85>, sensitivity ≤0.05 EU/mL). Batch 2026083310. Sample source: supplier-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.