Retatrutide 10mg supplier's lab test, lot BTCH-PE-99-334, September 2026
Optiq Health Labs tested Retatrutide 10mg on Sep 4, 2026. The shop is withheld. It measured 99.8% purity and 9.87 mg against 10 mg on the label.
- In the vial
- 9.87 mgThe label says 10 mg, so 1% less.
- Shop
- Shop withheld
- Tested by
- Optiq Health Labs
- Tested on
- Lot
- BTCH-PE-99-334
Optiq Health Labs has no public portal.
Only the lab can confirm this report, by email.
Sample source: supplier-provided. The shop's supplier had this batch tested before it reached the shop, and the shop passed the certificate on. How we weigh evidence →
All 1,546 Retatrutide lab tests →Retatrutide prices
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.8% | How much of what's in the vial is the target compound |
| Amount in the vial | 9.87 mglabel says 10 mg · 1% less | Whether you get the amount on the label |
| Endotoxin | ≤ 0.05 EU/mg · pass | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 10 mg · Lab measured 9.87 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 1% less means in a syringe
99% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.5 mg using the measured mass, against 2.5 mg on the label — 1% less.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 1190.OPT.260901 |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validOptiq Health Labs' portal doesn't show the numbers, so they can't be compared there. |
| Submitted via | Shop panel (bulk upload) |
| Counts as | Listed for information — supplier-provided, not counted |
| Sample source | Supplier-providedNo vial bought from the shop was tested. If the lot on your vial reads BTCH-PE-99-334, this is your batch's certificate. Supplier certificates are listed for information and don't count toward the Trust Score. |
| Submitted by | The shop |
HPLC purity analysis of GLP-3R 10mg, ordered by the selling shop's supplier and performed by Optiq Health Labs on September 4, 2026. Reported purity: 99.8%. Net content: 9.87 mg against 10 mg labeled (99% of label). Endotoxins: Pass (LAL, spec ≤ 0.05 EU/mg). Batch BTCH-PE-99-334. Sample source: supplier-provided. Certificate of analysis attached.
Related lab tests
The 1,544 other Retatrutide tests on Peptigrity have a typical purity of 99.80%. This one is 99.8%.