Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

GHK-Cu 100mg lab test from Red Dirt (RDR) Peptides, April 2026

Freedom Diagnostics tested GHK-Cu 100mg from Red Dirt (RDR) Peptides on Apr 11, 2026. It measured 99.866% purity and 90.6 mg against 100 mg on the label.

HPLC purity
99.866%
✓ Excellent
Excellent means 98% or higher.
In the vial
90.6 mgThe label says 100 mg, so 9% less.
Tested on
Lot
CU1002604
See the certificate ↓

Confirmed on Freedom Diagnostics' portal · checked Apr 11, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeRedD2604090177

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.866%How much of what's in the vial is the target compound
Amount in the vial90.6 mglabel says 100 mg · 9% lessWhether you get the amount on the label
EndotoxinPass (Replicate 1 & Replicate 2)Is it safe to inject? Checks for bacterial toxins
ContainerBlue Lyophilized Powder
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 100 mg · Lab measured 90.6 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 9% less means in a syringe

91% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 22.7 mg using the measured mass, against 25 mg on the label — 9% less.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Apr 11, 2026 · Batch CU1002604

About this test

How this certificate was checked

Report number2604090177
On the lab's portal✓ Confirmed Aug 12, 2026A Peptigrity staff member found this report on the laboratory's own public portal.date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Red Dirt (RDR) Peptides' Trust Score until Apr 11, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Aug 12, 2026
Summary

Independent HPLC purity analysis of GHK-Cu from Red Dirt (RDR) Peptides, performed by Freedom Diagnostics on April 11, 2026. Reported purity: 99.866%. Net content: 90.6 mg against 100 mg labeled (91% of label). Endotoxins: Pass (Replicate 1 & Replicate 2). Batch CU1002604. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

4 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.