Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

GHK-Cu 50mg lab test from Felix Chemical Supply, November 2025

Freedom Diagnostics tested GHK-Cu 50mg from Felix Chemical Supply on Nov 30, 2025. It measured 99.87% purity and 56.78 mg against 50 mg on the label.

HPLC purity
99.87%
✓ Excellent
Excellent means 98% or higher.
Amount measured
56.78 mgThe label says 50 mg, so 14% more.
Tested on
Lot
112425-KLO-C
See the certificate ↓

Not checked on Freedom Diagnostics' portal

This certificate carries no lookup code. Freedom Diagnostics has a public portal, so a report with a code can be looked up there.

Freedom Diagnostics' site says: “Enter that code below and click Look up . The Search Code is always the first 4 characters of your company name followed by your accession number.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.87%How much of what's in the vial is the target compound
Amount measured56.78 mglabel says 50 mg · 14% moreWhether you get the amount on the label
ContainerBlue Lyophilized Powder
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 50 mg · Lab measured 56.78 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Nov 30, 2025 · Batch 112425-KLO-C

About this test

How this certificate was checked

Report number112425-KLO-C
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Felix Chemical Supply's Trust Score until Nov 30, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed May 3, 2026
Summary

Independent HPLC purity analysis of GHK-Cu/KPV/BPC-157/Thymosin Beta-4 from Felix Chemical Supply, performed by Freedom Diagnostics on November 30, 2025. Reported purity: 99.87%. Net content: 56.78 mg against 50 mg labeled (114% of label). Tested content exceeds the labeled amount by 14%. Batch 112425-KLO-C. Sample source: shop-provided. Certificate of analysis attached.

Other lots of GHK-Cu from Felix Chemical Supply

LotTestedLabPurityvs labelLab's portal
042326-GHS-CApr 26, 2026Freedom Diagnostics99.81%119% of labelNot checked
041626-GHK-6Apr 19, 2026Freedom Diagnostics99.82%98% of labelNot checked
041326-GHS-1Apr 17, 2026Freedom Diagnostics99.97%97% of labelNot checked
022526-GLO-0 (black)Feb 27, 2026Freedom Diagnostics99.923%907% of labelNot checked
021025-G50-CFeb 12, 2026Freedom Diagnostics99.657%106% of labelNot checked
010226-KLO-9Jan 5, 2026Freedom Diagnostics99.829%201% of labelNot checked
122925-KLO-9Dec 31, 2025Freedom Diagnostics99.849%189% of labelNot checked
121525-GHK-5Dec 23, 2025Freedom Diagnostics99.954%99% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.