COA 2611041472 matches Freedom Diagnostics's public record. So this test doesn't rest on our review alone — the lab confirms it too.
Rivn2611041472This certificate covers purity, quantity, endotoxins, sterility, heavy metals and content uniformity.
Label 10 mg · Lab measured 10.64 mg
106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 6% more.
Several vials from this lot were tested; none of them was yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | 2611041472 |
|---|---|
| Portal lookup | ✓ Lab-verified |
| PDF vs portal | Freedom Diagnostics's portal shows validity only |
| Submitted via | Shop panel (bulk upload) |
| Weight | Counts as one lab test |
Independent HPLC purity analysis of ARA-290 from Rivn Research Peptides, performed by Freedom Diagnostics on November 7, 2026. Reported purity: 99.79%. Net content: 10.64 mg against 10 mg labeled (106% of label). Endotoxins: Pass. Sterility: passed. Content uniformity: passed. Heavy metals: Pass. Batch 342. Sample source: shop-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.
Community discussion