COA COA-2026-955274 matches ILS Laboratories's public record. So this test doesn't rest on our review alone — the lab confirms it too.
VMMLNLP3This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Independent HPLC purity analysis of TB-500 from elyriabio peptides, performed by ILS Laboratories on August 7, 2026. Reported purity: 99.7%. Net content: 10.6 mg against 10 mg labeled (106% of label). Heavy metals: ICP-MS: As 0.0289 ppm, Cd 0.0142 ppm, Pb 0.0278 ppm, Hg 0.0472 ppm, Cr 0.0184 ppm – all Pass. Batch 030371. Sample source: shop-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.