Selank 5mg lab test from Kensington Labs, November 2025
Janoshik Labs tested Selank 5mg from Kensington Labs on Nov 3, 2025. It measured 99.274% purity and 6.35 mg against 5 mg on the label.
- In the vial
- 6.35 mgThe label says 5 mg, so 27% more.
- Tested by
- Janoshik Labs
- Tested on
- Lot
- SLN-663PY
Not checked on Janoshik Labs' portal
This certificate carries no lookup code. Janoshik Labs has a public portal, so a report with a code can be looked up there.
Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 350 Selank lab tests →Selank pricesKensington Labs reviews and all 22 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.274% | How much of what's in the vial is the target compound |
| Amount in the vial | 6.35 mglabel says 5 mg · 27% more | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 5 mg · Lab measured 6.35 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 27% more means in a syringe
127% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.6 mg using the measured mass, against 1.3 mg on the label — 27% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | SLN-663PY |
|---|---|
| On the lab's portal | Not checkedThis certificate has not been checked against the laboratory's public portal. |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Kensington Labs' Trust Score until Nov 3, 2027. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | Peptigrity Team Member 02 · Peptigrity team · filed Mar 13, 2026 |
Independent HPLC purity analysis of SELANK from Kensington Labs, performed by Janoshik Labs on November 3, 2025. Reported purity: 99.274%. Net content: 6.35 mg against 5 mg labeled (127% of label). Tested content exceeds the labeled amount by 27%. Batch SLN-663PY. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 347 other Selank tests on Peptigrity have a typical purity of 99.73%. This one is 99.274%.

Community discussion