HomeLab Tests Unknown Brand, Retatrutide
Purity · pass✓ Lab-verifiedShop-provided sample

Retatrutide × Unknown Brand — Lab Test, July 2026

LotRT30-655look this batch up across every shop →
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.81%
Excellent purity only
BrandUnknown Brand
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA ACC-2026-6117 matches ILS Laboratories's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup codeJKVDPMRA

Test results

6 data points
Purity
99.81%
Endotoxins
Not tested
Heavy metals
Not tested
Stated qty
30 mg
Tested qty
31.07 mg
Qty match
104% of labeled · +4%
Batch / Lot
RT30-655
COA number
ACC-2026-6117
Tested by
ILS LaboratoriesView profile →

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 30 mg · Lab measured 31.07 mg

104% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 7.8 mg using the measured mass, against 7.5 mg on the label — 4% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report numberACC-2026-6117
Portal lookup✓ Lab-verified
Checked22 Jul 2026date taken from the record, not from a logged check
Checked byPeptigrity staff, against the lab's portal
PDF vs portalILS Laboratories's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of Retatrutide from Unknown brand, performed by ILS Laboratories on July 1, 2026. Reported purity: 99.81%. Net content: 31.07 mg against 30 mg labeled (104% of label). Batch RT30-655. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by ILS Laboratories · Jul 01, 2026 · Batch RT30-655

Related lab tests

4 tests

The 1317 other Retatrutide tests on Peptigrity range from 64.06% to 100.00%. This one sits at 99.81%.

More Retatrutide tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.

Submit a lab test →