COA #68805 matches Janoshik Labs's public record. So this test doesn't rest on our review alone — the lab confirms it too.
MNAY7JT1PUFLThis is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Label 20 mg · Lab measured 22.93 mg
115% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 5.7 mg using the measured mass, against 5 mg on the label — 15% more.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | #68805 |
|---|---|
| Portal lookup | ✓ Lab-verified |
| Checked | 24 Jul 2026date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| PDF vs portal | Janoshik Labs's portal shows validity only |
| Weight | Counts as one lab test |
Independent HPLC purity analysis of Retatrutide from Unknown brand, performed by Janoshik Labs on June 24, 2025. Reported purity: 99.695%. Net content: 22.93 mg against 20 mg labeled (115% of label). Tested content exceeds the labeled amount by 15%. Batch F21750628. Sample source: shop-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.