Retatrutide 12mg lab test, lot RTT2632, September 2026
Chromate tested Retatrutide 12mg on Sep 3, 2026. The shop is withheld. It measured 99.677% purity and 12.02 mg against 12 mg on the label.
- In the vial
- 12.02 mgThe label says 12 mg.
- Shop
- Shop withheld
- Tested by
- Chromate
- Tested on
- Lot
- RTT2632
Confirmed on Chromate's portal · checked Sep 3, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
7X662J8M9UY4Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 1,563 Retatrutide lab tests →Retatrutide prices
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.677% | How much of what's in the vial is the target compound |
| Amount in the vial | 12.02 mglabel says 12 mg | Whether you get the amount on the label |
| Endotoxin | < 5 EU/vial | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | < 50 ppb | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: sterility. It may still be on the certificate below. If it isn't there either, this test says nothing about it.
What’s in the vial
Label 12 mg · Lab measured 12.02 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What this means in a syringe
100% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 3 mg on both the label figure and the measured one.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 39032 |
|---|---|
| On the lab's portal | ✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal. |
| What the portal shows | That the report is validChromate's portal doesn't show the numbers, so they can't be compared there. |
| Submitted via | Peptigrity staff |
| Counts as | One lab test |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | @Peptigrity 👑 Legend |
Independent HPLC purity analysis of Retatrutide, performed by Chromate on September 3, 2026. Reported purity: 99.677%. Net content: 12.02 mg against 12 mg labeled (100% of label). Endotoxins: < 5 EU/vial. Heavy metals: < 50 ppb. Batch RTT2632. Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 1,560 other Retatrutide tests on Peptigrity have a typical purity of 99.80%. This one is 99.677%.

Community discussion