COA OUTL-RETA-30-060626-02-GT matches Testides's public record. So this test doesn't rest on our review alone — the lab confirms it too.
OUTL-RETA-30-060626-02-GTThis is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Label 30 mg · Lab measured 33.83 mg
113% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 8.5 mg using the measured mass, against 7.5 mg on the label — 13% more.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | OUTL-RETA-30-060626-02-GT |
|---|---|
| Portal lookup | ✓ Lab-verified |
| PDF vs portal | Testides's portal shows validity only |
| Weight | Counts as one lab test |
Independent HPLC purity analysis of Retatrutide from Unknown brand, performed by Testides on July 2, 2026. Reported purity: 99.94%. Net content: 33.83 mg against 30 mg labeled (113% of label). Tested content exceeds the labeled amount by 13%. Endotoxins: Kinetic LAL (USP <85>) < 0.125 EU/mL - PASS. Sample source: shop-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.