ForumRequest to add shop: Boruimei· Shop talk · last reply 1 d ago
✓ Purity · pass✓ Lab-verifiedSupplier-provided sample

Retatrutide — supplier's lab test, June 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by @Boruimei ● Member
Sample source: supplier-provided. The shop's supplier had this batch tested before it reached the shop, and the shop passed the certificate on. No vial bought from the shop was tested. If the lot on your vial reads RT30-061526, this is your batch's certificate. Supplier certificates are listed for information and don't count toward the Trust Score.How we weigh evidence →
HPLC Purity
99.869%
✓ Excellent purity only
Sold byShop withheld
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA 157290 matches Janoshik Labs's public record. So this test doesn't rest on our review alone — the lab confirms it too.

The portal confirms the certificate. It can't show that a vial you buy from the shop is from this batch — compare the lot on yours.

Lookup codeXMFVLMFXIUAM

Test results

6 data points
Purity
99.869%
Endotoxins
Not tested
Sterility
Not on file
Heavy metals
Not tested
Stated qty
30 mg
Tested qty
22.46 mg
Qty match
75% of labeled · -25%
Batch / Lot
RT30-061526
COA number
157290
Tested by
Janoshik LabsView profile →

Not on file for this certificate: endotoxins, sterility and heavy metals. A purity figure says nothing about those.

About this test

What’s in the vial

Label 30 mg · Lab measured 22.46 mg

75% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 5.6 mg using the measured mass, against 7.5 mg on the label — 25% less.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report number157290
Portal lookup✓ Lab-verified
PDF vs portalJanoshik Labs's portal shows validity only
WeightListed for information — supplier-provided, not counted

HPLC purity analysis of Retatrutide, ordered by the selling shop's supplier and performed by Janoshik Labs on June 5, 2026. Reported purity: 99.869%. Net content: 22.46 mg against 30 mg labeled (75% of label). Tested content is 25% below the labeled amount. Batch RT30-061526. Sample source: supplier-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by Janoshik Labs · Jun 05, 2026 · Batch RT30-061526

Related lab tests

4 tests

The 1428 other Retatrutide tests on Peptigrity range from 64.06% to 100.00%. This one sits at 99.87%.

More Retatrutide tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?