Forumshangdong yixin · Shop talk · 8 replies
✓ Purity · pass✓ Lab-verifiedShop-provided sample

Retatrutide — lab test, lot CR-3XAG-30MG-2606-2, June 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by @Peptigrity 👑 Legend
Sample source: shop-provided. The shop chose and sent this vial. The Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.How we weigh evidence →
HPLC Purity
99.65%
✓ Excellent purity only
BrandShop withheld
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA -2026-O1Y8QY matches ILS Laboratories's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup codeRWJRBNEQ

Test results

8 data points
Purity
99.65%
Endotoxins
0.096 EU/mL
Sterility
Not on file
Heavy metals
Not Detected
Stated qty
30 mg
Tested qty
31.71 mg
Qty match
106% of labeled · +6%
Batch / Lot
CR-3XAG-30MG-2606-2
COA number
-2026-O1Y8QY
Tested by
ILS LaboratoriesView profile →

Not on file for this certificate: sterility. A purity figure says nothing about that.

About this test

What’s in the vial

Label 30 mg · Lab measured 31.71 mg

106% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 7.9 mg using the measured mass, against 7.5 mg on the label — 6% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report number-2026-O1Y8QY
Portal lookup✓ Lab-verified
PDF vs portalILS Laboratories's portal shows validity only
Submitted viaPeptigrity staff
WeightCounts as one lab test

Independent HPLC purity analysis of Retatrutide, performed by ILS Laboratories on June 26, 2026. Reported purity: 99.65%. Net content: 31.71 mg against 30 mg labeled (106% of label). Endotoxins: 0.096 EU/mL. Heavy metals: Not Detected. Batch CR-3XAG-30MG-2606-2. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by ILS Laboratories · Jun 26, 2026 · Batch CR-3XAG-30MG-2606-2

Related lab tests

4 tests

The 1525 other Retatrutide tests on Peptigrity range from 64.06% to 100.00%. This one sits at 99.65%.

More Retatrutide tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.