freedomdiagnosticstesting.com publishes a public verification portal. Any test attributed to this lab can be looked up and confirmed directly with the lab — so this result doesn't rest on our review alone.
This certificate carries no lookup code.
This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Label 30 mg · Lab measured 29.12 mg
97% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 7.3 mg using the measured mass, against 7.5 mg on the label — 3% less.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
Independent HPLC purity analysis of N-Acetyl Semax from OROS Research, performed by freedomdiagnosticstesting.com on February 28, 2026. Reported purity: 99.6%. Net content: 29.12 mg against 30 mg labeled (97% of label). Endotoxins: ≤ 0.05 EU/mL. Batch 1625200. Sample source: shop-provided. Certificate of analysis attached.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.