HomeLab Tests novalabs.is peptides, Melanotan II (MT-2)
Purity · pass✓ Lab-verifiedBatch · Black CapShop-provided sample

Melanotan II (MT-2) × novalabs.is peptides — Lab Test, July 2026

Tested · submitted by Peptigrity Team Member 01PEPTIGRITY TEAM
Filed by Peptigrity Team Member 01 ·
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.89%
Excellent purity only
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA 2607200180 matches freedomdiagnosticstesting.com's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup codeNova2607200180

Test results

8 data points
Purity
99.89%
Endotoxins
Replicate 1: Pass; Replicate 2: Pass - Assay Sensitivity ≤0.05 EU/mL
Heavy metals
Not tested
Stated qty
10 mg
Tested qty
9.36 mg
Qty match
94% of labeled · -6%
Batch / Lot
Black Cap
COA number
2607200180
Container
White Lyophilized Powder
Tested by

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 10 mg · Lab measured 9.36 mg

94% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.3 mg using the measured mass, against 2.5 mg on the label — 6% less.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report number2607200180
Portal lookup✓ Lab-verified
PDF vs portalfreedomdiagnosticstesting.com's portal shows validity only
WeightCounts as one lab test

Independent HPLC purity analysis of Melanotan II (MT-2) from novalabs.is peptides, performed by freedomdiagnosticstesting.com on July 21, 2026. Reported purity: 99.89%. Net content: 9.36 mg against 10 mg labeled (94% of label). Endotoxins: Replicate 1: Pass; Replicate 2: Pass - Assay Sensitivity ≤0.05 EU/mL. Batch Black Cap. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by freedomdiagnosticstesting.com · Jul 21, 2026 · Batch Black Cap

Related lab tests

8 tests

The 270 other Melanotan II (MT-2) tests on Peptigrity range from 97.77% to 99.99%. This one sits at 99.89%.

More from novalabs.is peptides
More Melanotan II (MT-2) tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.