Forumshangdong yixin · Shop talk · 8 replies
✓ Purity · pass✓ Sterility · pass✓ Lab-verifiedShop-provided sample

Melanotan II (MT-2) × Crush Research — lab test, June 2026

Lotlook this batch up across every shop →Check another lot
Tested · submitted by @Peptigrity 👑 Legend
Sample source: shop-provided. The shop chose and sent this vial. The Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.How we weigh evidence →
HPLC Purity
99.73%
✓ Excellent purity only
Counts toward Crush Research's Trust Score until 1 Jun 2028
↓ Download COA
Independently confirmed on the lab’s portal✓ Extra check

COA -2026-73RMCX matches ILS Laboratories's public record. So this test doesn't rest on our review alone — the lab confirms it too.

Lookup code7DWZNLVU

Test results

9 data points
Purity
99.73%
Endotoxins
0.976 EU/mL
Sterility
Pass — no growthLab's note: No Growth
Heavy metals
Not Detected
Stated qty
10 mg
Tested qty
10.81 mg
Qty match
108% of labeled · +8%
Batch / Lot
CR-MT2-10-2605-1
COA number
-2026-73RMCX
Tested by
ILS LaboratoriesView profile →

This certificate covers purity, quantity, endotoxins, sterility and heavy metals.

About this test

What’s in the vial

Label 10 mg · Lab measured 10.81 mg

108% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.7 mg using the measured mass, against 2.5 mg on the label — 8% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Verification trail
Report number-2026-73RMCX
Portal lookup✓ Lab-verified
PDF vs portalILS Laboratories's portal shows validity only
Submitted viaPeptigrity staff
WeightCounts as one lab test

Independent HPLC purity analysis of Melanotan II (MT-2) from Crush Research, performed by ILS Laboratories on June 1, 2026. Reported purity: 99.73%. Net content: 10.81 mg against 10 mg labeled (108% of label). Endotoxins: 0.976 EU/mL. Sterility: passed. Heavy metals: Not Detected. Batch CR-MT2-10-2605-1. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by ILS Laboratories · Jun 01, 2026 · Batch CR-MT2-10-2605-1

Other lots of Melanotan II (MT-2) from Crush Research

LotTestedLabPurityvs labelStatus
CR-MT210MG-082824 Aug 2026ILS Laboratories99.9%105%Unverified
CR-MT210-2603-12 Apr 2026BTLabs99.8%98%Lab has no portal

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

5 tests

The 290 other Melanotan II (MT-2) tests on Peptigrity range from 97.77% to 99.99%. This one sits at 99.73%.

More from Crush Research
More Melanotan II (MT-2) tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.