HomeLab Tests peptidology.co, GHK-Cu
Purity · passShop-provided sample

GHK-Cu × peptidology.co — lab test, July 2025

Sample label: Peptidology
Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99.72%
Excellent purity only
↓ Download COA
Independent verification available

Vanguard Laboratory publishes a public verification portal. Any test attributed to this lab can be looked up and confirmed directly with the lab — so this result doesn't rest on our review alone.

This certificate carries no lookup code.

Test results

7 data points
Purity
99.72%
Endotoxins
Not tested
Heavy metals
Not tested
Stated qty
50 mg
Tested qty
65.11 mg
Qty match
130% of labeled · +30%
Batch / Lot
01-029-PD-1358
Container
Three brown vials with purple caps
Tested by
Vanguard LaboratoryView profile →

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 50 mg · Lab measured 65.11 mg

130% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 16.3 mg using the measured mass, against 12.5 mg on the label — 30% more.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Independent HPLC purity analysis of GHK-Cu from peptidology.co, performed by Vanguard Laboratory on July 29, 2025. Reported purity: 99.72%. Net content: 65.11 mg against 50 mg labeled (130% of label). Tested content exceeds the labeled amount by 30%. Batch 01-029-PD-1358. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by Vanguard Laboratory · Jul 29, 2025 · Batch 01-029-PD-1358

Other lots of GHK-Cu from peptidology.co

LotTestedLabPurityvs labelStatus
01-029-PD-13532 Apr 2025Vanguard Laboratory99.5%106%Unverified

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

The 810 other GHK-Cu tests on Peptigrity range from 95.76% to 100.00%. This one sits at 99.72%.

More from peptidology.co
More GHK-Cu tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.