HomeLab Tests stratfordpeptides.com, BPC-157
Purity · passShop-provided sample

BPC-157 × stratfordpeptides.com — lab test, February 2026

Sample label: Stratford Peptides
Lotlook this batch up across every shop →Check another lot
Tested · submitted by Peptigrity Team Member 02PEPTIGRITY TEAM
Sample source: shop-provided. The shop chose and sent this vial. Samples bought at retail by a member carry more weight.How we weigh evidence →
HPLC Purity
99%
Excellent purity only
↓ Download COA
Independent verification available

Analiza Białek publishes a public verification portal. Any test attributed to this lab can be looked up and confirmed directly with the lab — so this result doesn't rest on our review alone. Look up by order number and password

This certificate carries no lookup code.

Test results

7 data points
Purity
99%
Endotoxins
Not tested
Heavy metals
Not tested
Stated qty
20 mg
Tested qty
18.48 mg
Qty match
92% of labeled · -8%
Batch / Lot
100012724
Container
White powder in glass vial
Tested by
Analiza BiałekView profile →

This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.

About this test

What’s in the vial

Label 20 mg · Lab measured 18.48 mg

92% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 4.6 mg using the measured mass, against 5 mg on the label — 8% less.

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Independent HPLC purity analysis of BPC-157/TB-500 from stratfordpeptides.com, performed by Analiza Białek on February 25, 2026. Reported purity: 99%. Net content: 18.48 mg against 20 mg labeled (92% of label). Batch 100012724. Sample source: shop-provided. Certificate of analysis attached.

Certificate of analysis

Original document
Issued by Analiza Białek · Feb 25, 2026 · Batch 100012724

Other lots of BPC-157 from stratfordpeptides.com

LotTestedLabPurityvs labelStatus
10001407327 Apr 2026Analiza Białek99%158%Unverified
10001317113 Mar 2026Analiza Białek99.61%106%Unverified
10001316913 Mar 2026Analiza Białek99.39%101%Unverified

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

The 874 other BPC-157 tests on Peptigrity range from 91.65% to 100.00%. This one sits at 99.00%.

More from stratfordpeptides.com
More BPC-157 tests
♡ Likes · 0

Community discussion

0 comments

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.