Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

BPC-157 80mg lab test from HkRoids, February 2026

Testides tested BPC-157 80mg from HkRoids on Feb 22, 2026. It measured 99.83% purity and 85.88 mg against 80 mg on the label.

HPLC purity
99.83%
✓ Excellent
Excellent means 98% or higher.
Amount measured
85.88 mgThe label says 80 mg, so 7% more.
Tested by
Testides
Tested on
Lot
M1-01012026D028
See the certificate ↓

Testides has no public portal.

Only the lab can confirm this report, by email.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.83%How much of what's in the vial is the target compound
Amount measured85.88 mglabel says 80 mg · 7% moreWhether you get the amount on the label
ContainerBlue lyophilized powder
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 80 mg · Lab measured 85.88 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Certificate of analysis

Original document
Issued by Testides · Feb 22, 2026 · Batch M1-01012026D028

About this test

How this certificate was checked

Report numberM1-01012026D028
On the lab's portalLab has no portalThis laboratory publishes no public lookup, so the report cannot be confirmed independently.
What the portal showsThat the report is validTestides' portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward HkRoids' Trust Score until Feb 22, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed May 14, 2026
Summary

Independent HPLC purity analysis of BPC-157/TB-500/GHK-Cu/KPV from HkRoids, performed by Testides on February 22, 2026. Reported purity: 99.83%. Net content: 85.88 mg against 80 mg labeled (107% of label). Batch M1-01012026D028. Sample source: shop-provided. Certificate of analysis attached.

Other lots of BPC-157 from HkRoids

LotTestedLabPurityvs labelLab's portal
01.17Mar 3, 2026Vanguard Laboratory99.9%104% of labelNot checked
BPC-262010-B1Feb 22, 2026Vanguard Laboratory99.73%99% of labelNot checked
05672Nov 5, 2025Freedom Diagnostics98.813%132% of labelNot checked
2025.9.9.BP10Oct 8, 2025Freedom Diagnostics99.28%96% of labelNot checked
0362Jun 16, 2025Freedom Diagnostics99.55%101% of labelNot checked
WP-250316-28May 9, 2025Chromate99.523%103% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

5 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.