Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

BPC-157 10mg lab test from Optimum Formula, February 2026

Vanguard Laboratory tested BPC-157 10mg from Optimum Formula on Feb 6, 2026. It measured 99.8% purity and 10.17 mg against 10 mg on the label.

HPLC purity
99.8%
✓ Excellent
Excellent means 98% or higher.
In the vial
10.17 mgThe label says 10 mg, so 2% more.
Tested on
Lot
R34N8
See the certificate ↓

Not checked on Vanguard Laboratory's portal

This certificate carries no lookup code. Vanguard Laboratory has a public portal, so a report with a code can be looked up there.

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.8%How much of what's in the vial is the target compound
Amount in the vial10.17 mglabel says 10 mg · 2% moreWhether you get the amount on the label
ContainerYellow Cap
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 10.17 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 2% more means in a syringe

102% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.5 mg using the measured mass, against 2.5 mg on the label — 2% more.

Certificate of analysis

Original document
Issued by Vanguard Laboratory · Feb 6, 2026 · Batch R34N8

About this test

How this certificate was checked

Report numberV260119-7 003
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validVanguard Laboratory's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward Optimum Formula's Trust Score until Feb 6, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Aug 12, 2026
Summary

Independent HPLC purity analysis of BPC-157 from Optimum Formula, performed by Vanguard Laboratory on February 6, 2026. Reported purity: 99.8%. Net content: 10.17 mg against 10 mg labeled (102% of label). Batch R34N8. Sample source: shop-provided. Certificate of analysis attached.

Other lots of BPC-157 from Optimum Formula

LotTestedLabPurityvs labelLab's portal
#HX4RRTJun 4, 2026ILS Laboratories99.8%103% of label✓ Confirmed
8KJ3PMar 22, 2026Kovera Labs99.934%118% of label✓ Confirmed

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.