BPC-157 lab test from Direct Research Supply, September 2026
Janoshik Labs tested BPC-157 from Direct Research Supply on Sep 15, 2026. It measured 99.242% purity and 10.38 mg against 10 mg on the label.
- In the vial
- 10.38 mgThe label says 10 mg, so 4% more.
- Tested by
- Janoshik Labs
- Tested on
Confirmed on Janoshik Labs' portal · checked Sep 15, 2026
Peptigrity looked this report up on the lab's own site and it's there. You can check it too.
YXTZ24MX1YGISample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →
All 954 BPC-157 lab tests →BPC-157 pricesDirect Research Supply reviews and all 7 lab tests
Test results
| Test | Result | What it tells you |
|---|---|---|
| Purity (HPLC) | 99.242% | How much of what's in the vial is the target compound |
| Amount in the vial | 10.38 mglabel says 10 mg · 4% more | Whether you get the amount on the label |
| Endotoxin | Not recorded | Is it safe to inject? Checks for bacterial toxins |
| Heavy metals | Not recorded | Could there be metal contamination? |
| Sterility | Not recorded | Is it safe to inject? Checks for live bacteria or fungi |
Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.
What’s in the vial
Label 10 mg · Lab measured 10.38 mg
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
What 4% more means in a syringe
104% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.6 mg using the measured mass, against 2.5 mg on the label — 4% more.
Certificate of analysis
About this test
How this certificate was checked
| Report number | 232190 |
|---|---|
| On the lab's portal | ✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal. |
| What the portal shows | That the report is validJanoshik Labs' portal doesn't show the numbers, so they can't be compared there. |
| Counts as | One lab testCounts toward Direct Research Supply's Trust Score until Sep 15, 2028. |
| Sample source | Shop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself. |
| Submitted by | @Directresearchsupply 💬 Contributor |
Independent HPLC purity analysis of BPC-157 from Direct Research Supply, performed by Janoshik Labs on September 15, 2026. Reported purity: 99.242%. Net content: 10.38 mg against 10 mg labeled (104% of label). Sample source: shop-provided. Certificate of analysis attached.
Related lab tests
The 951 other BPC-157 tests on Peptigrity have a typical purity of 99.48%. This one is 99.242%.

Community discussion