Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

BPC-157 0.5mg lab test from Amino USA, June 2025

BioRegen tested BPC-157 0.5mg from Amino USA on Jun 30, 2025. It measured 99.08% purity and 0.59 mg against 0.5 mg on the label.

HPLC purity
99.08%
✓ Excellent
Excellent means 98% or higher.
In the vial
0.59 mgThe label says 0.5 mg, so 18% more.
Tested by
BioRegen
Tested on
Lot
25BPC500-0001
See the certificate ↓

Not public on BioRegen's site

BioRegen shows a certificate online only when its client makes it public. To check this one, enter the report number and the validation key printed at the top of the certificate on BioRegen's verify page.

Report number10705

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.08%How much of what's in the vial is the target compound
Amount in the vial0.59 mglabel says 0.5 mg · 18% moreWhether you get the amount on the label
ContainerWhite powder in capsule form
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 0.5 mg · Lab measured 0.59 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 18% more means in a syringe

118% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 148 mcg using the measured mass, against 125 mcg on the label — 18% more.

Certificate of analysis

Original document
Issued by BioRegen · Jun 30, 2025 · Batch 25BPC500-0001

About this test

How this certificate was checked

Report number10705
On the lab's siteNot checkedBioRegen's page for this certificate isn't public.
Counts asOne lab testCounts toward Amino USA's Trust Score until Jun 30, 2027.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Apr 28, 2026
Summary

Independent HPLC purity analysis of BPC-157 from Amino USA, performed by BioRegen on June 30, 2025. Reported purity: 99.08%. Net content: 0.59 mg against 0.5 mg labeled (118% of label). Tested content exceeds the labeled amount by 18%. Batch 25BPC500-0001. Sample source: shop-provided. Certificate of analysis attached.

Other lots of BPC-157 from Amino USA

LotTestedLabPurityvs labelLab's portal
26BPC15-0004Apr 7, 2026Freedom Diagnostics99.242%115% of labelNot checked
26BPC10-0007Mar 5, 2026BioRegen99.49%137% of labelNot checked
26BPC500-0002Feb 11, 2026BioRegen99.17%103% of labelNot checked
25BPCTB55-0006Nov 10, 2025BioRegen99.88%109% of labelNot checked
25BPC15-0003Nov 10, 2025BioRegen99.89%95% of labelNot checked
25BPC10-0006Nov 10, 2025BioRegen99.89%112% of labelNot checked
25BPC5-0008Nov 4, 2025BioRegen99.92%98% of labelNot checked
25BPC20-0001Oct 8, 2025BioRegen99.84%112% of labelNot checked

Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.

Related lab tests

8 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.