Forumslovakia doping bust: 13 detained, 80+ kinds of peptides and two labs seized · Shop talk · 3 replies

BPC-157 10mg lab test from Alux Research, August 2026

Freedom Diagnostics tested BPC-157 10mg from Alux Research on Aug 13, 2026. It measured 99.12% purity and 8.41 mg against 10 mg on the label.

HPLC purity
99.12%
✓ Excellent
Excellent means 98% or higher.
In the vial
8.41 mgThe label says 10 mg, so 16% less.
Tested on
See the certificate ↓

Confirmed on Freedom Diagnostics' portal · checked Aug 13, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codeAlux2608100466

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.12%How much of what's in the vial is the target compound
Amount in the vial8.41 mglabel says 10 mg · 16% lessWhether you get the amount on the label
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 10 mg · Lab measured 8.41 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What 16% less means in a syringe

84% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 2.1 mg using the measured mass, against 2.5 mg on the label — 16% less.

Certificate of analysis

Original document
Issued by Freedom Diagnostics · Aug 13, 2026 · Batch Red Cap

About this test

How this certificate was checked

Report number2608100466
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validFreedom Diagnostics' portal doesn't show the numbers, so they can't be compared there.
Submitted viaPeptigrity staff
Counts asOne lab testCounts toward Alux Research's Trust Score until Aug 13, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@Peptigrity 👑 Legend
Summary

Independent HPLC purity analysis of BPC-157 from Alux Research, performed by Freedom Diagnostics on August 13, 2026. Reported purity: 99.12%. Net content: 8.41 mg against 10 mg labeled (84% of label). Tested content is 16% below the labeled amount. Batch Red Cap. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

6 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.