ForumRetatrutide: 1, 2 or 3 mL of BAC water — what do you use, and why? · Retatrutide · 10 replies

AOD-9604 5mg lab test from True Research Labs, May 2026

Horizon Analytical tested AOD-9604 5mg from True Research Labs on May 19, 2026. It measured 99.65% purity and 5.02 mg against 5 mg on the label.

HPLC purity
99.65%
✓ Excellent
Excellent means 98% or higher.
In the vial
5.02 mgThe label says 5 mg.
Tested on
Lot
TRL-4602824
See the certificate ↓

Not checked on Horizon Analytical's portal

This certificate carries no lookup code. Horizon Analytical has a public portal, so a report with a code can be looked up there.

Horizon Analytical's site says: “Search by lot number or sample ID to access any lab report.”

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.65%How much of what's in the vial is the target compound
Amount in the vial5.02 mglabel says 5 mgWhether you get the amount on the label
ContainerWhite Lyophilized Powder
EndotoxinNot recordedIs it safe to inject? Checks for bacterial toxins
Heavy metalsNot recordedCould there be metal contamination?
SterilityNot recordedIs it safe to inject? Checks for live bacteria or fungi

Not recorded for this test: endotoxin, heavy metals and sterility. They may still be on the certificate below. If they aren't there either, this test says nothing about them.

What’s in the vial

Label 5 mg · Lab measured 5.02 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

What this means in a syringe

100% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 1.3 mg on both the label figure and the measured one.

Certificate of analysis

Original document
Issued by Horizon Analytical · May 19, 2026 · Batch TRL-4602824

About this test

How this certificate was checked

Report numberTRL-4602824
On the lab's portalNot checkedThis certificate has not been checked against the laboratory's public portal.
What the portal showsThat the report is validHorizon Analytical's portal doesn't show the numbers, so they can't be compared there.
Counts asOne lab testCounts toward True Research Labs' Trust Score until May 19, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted byPeptigrity Team Member 02 · Peptigrity team · filed Aug 13, 2026
Summary

Independent HPLC purity analysis of AOD-9604 from True Research Labs, performed by Horizon Analytical on May 19, 2026. Reported purity: 99.65%. Net content: 5.02 mg against 5 mg labeled (100% of label). Batch TRL-4602824. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

7 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.