COA 2604150229 matches freedomdiagnosticstesting.com's public record. So this test doesn't rest on our review alone — the lab confirms it too.
ezPe2604150229This is a purity and identity analysis. Sterility, endotoxins, and heavy metals were not screened — a high purity figure says nothing about those.
Label 50 mg · Lab measured 53.54 mg
107% of label, basis not stated — shown as printed. Reconstituted with 2 mL, a 50-unit draw holds 13.4 mg using the measured mass, against 12.5 mg on the label — 7% more.
One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.
| Report number | 2604150229 |
|---|---|
| Portal lookup | ✓ Lab-verified |
| Checked | 24 Jul 2026date taken from the record, not from a logged check |
| Checked by | Peptigrity staff, against the lab's portal |
| PDF vs portal | freedomdiagnosticstesting.com's portal shows validity only |
| Weight | Counts as one lab test |
Independent HPLC purity analysis of SS-31 from ezpeps.com, performed by freedomdiagnosticstesting.com on April 16, 2026. Reported purity: 99.91%. Net content: 53.54 mg against 50 mg labeled (107% of label). Endotoxins: Pass, ≤0.05 EU/mL (Replicate 1 & 2). Batch 26-U3-PBT / SS500305. Sample source: shop-provided. Certificate of analysis attached.
| Lot | Tested | Lab | Purity | vs label | Status |
|---|---|---|---|---|---|
| 26-U5-PCT / SS500514 | 23 Jun 2026 | ILS Laboratories | 99.94% | 103% | ✓ Lab-verified |
| SS50-1030 | 12 Nov 2025 | Janoshik Labs | 99.694% | 122% | ✓ Lab-verified |
Batches this shop has published a certificate for, newest first. A lot whose printed value cannot identify a batch is not listed.
Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.
Community discussion