BPC-157 + TB-500 Blend 20mg lab test from Source Research, May 2026

ILS Laboratories tested BPC-157 + TB-500 Blend 20mg from Source Research on May 11, 2026. It measured 99.94% purity and 21.17 mg against 20 mg on the label.

HPLC purity
99.94%
✓ Excellent
Excellent means 98% or higher.
Amount measured
21.17 mgThe label says 20 mg, so 6% more.
Tested on
Sterility
✓ Pass · no growth
Lot
sr-bpctb-260316-001
See the certificate ↓

Confirmed on ILS Laboratories' portal · checked May 11, 2026

Peptigrity looked this report up on the lab's own site and it's there. You can check it too.

Lookup codePJNWXLGE

Sample source: shop-provided. The shop chose and sent this vial. How we weigh evidence →

Test results

what the lab measured
TestResultWhat it tells you
Purity (HPLC)99.94%How much of what's in the vial is the target compound
Amount measured21.17 mglabel says 20 mg · 6% moreWhether you get the amount on the label
Endotoxin< 0.25 EU/mL · passIs it safe to inject? Checks for bacterial toxins
Heavy metalsICP-MS: As, Cd, Cr, Hg, Pb not detected (Pass)Could there be metal contamination?
SterilityPass — no growthIs it safe to inject? Checks for live bacteria or fungi

This certificate covers purity, quantity, endotoxins, sterility and heavy metals.

What’s in the vial

Label 20 mg · Lab measured 21.17 mg

One vial from this lot was weighed by the laboratory, not yours. This page reports what the certificate says; it does not recommend a dose.

Certificate of analysis

Original document
Issued by ILS Laboratories · May 11, 2026 · Batch sr-bpctb-260316-001

About this test

How this certificate was checked

Report numberCOA-2026--GYDKD
On the lab's portal✓ ConfirmedA Peptigrity staff member found this report on the laboratory's own public portal.
What the portal showsThat the report is validILS Laboratories' portal doesn't show the numbers, so they can't be compared there.
Submitted viaShop panel (bulk upload)
Counts asOne lab testCounts toward Source Research's Trust Score until May 11, 2028.
Sample sourceShop-providedThe Trust Score counts it like any other published test; who sourced the vial is shown so you can weigh it yourself.
Submitted by@SourceResearch 💬 Contributor
Summary

Independent HPLC purity analysis of BPC-157 + TB-500 Blend 20mg from Source Research, performed by ILS Laboratories on May 11, 2026. Reported purity: 99.94%. Net content: 21.17 mg against 20 mg labeled (106% of label). Endotoxins: < 0.25 EU/mL (USP <85>, Pass). Sterility: passed. Heavy metals: ICP-MS: As, Cd, Cr, Hg, Pb not detected (Pass). Batch sr-bpctb-260316-001. Sample source: shop-provided. Certificate of analysis attached.

Related lab tests

2 tests

Community discussion

0 comments · ♡ 0 likes

Join the discussion — sign in to leave a comment on this lab test.

Sign in to comment →

Have you tested this peptide?

Submit your third-party lab test to help the community verify purity claims. Every report is reviewed before publication.